Bacharach Gas Pup Instruções de Operação Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 58
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
GA-40 T plus OPERATION
19
0 to 9 . - the alphanumeric keys enter numbers in digital mode or letters in alphabetical mode.
Each key has a three letter designation. The first press enters the first letter, the next
presses the second and the third letter. Key presses in alphabetical mode does not
move the cursor.
0 - (SPACE) prints 0 number in digital and the space character in alphabetical mode.
The space moves all the next characters one position to the right..
C - (DEL) erases the character above cursor position. This moves all the following
characters one position to the left.
ENTER - ends the entering of a text (if only one line is edited - e.g. the name of a fuel) or
moves the cursor down to the next line (if there are several lines in the edited text -
e.g. the report header)
STORE - end the editing of a header or footer - it enables the storage of edited text. If you do
not need to store the contents of header or footer you should leave the screen by
pressing the MENU key.
5.2 Basic operating instructions
5.2.1 Setting-up the analyser
Connect the components of the analyser system
G Attach the hose to the connector GAS. The plug from the heated hose connects to the socket
HEATED LINE.
G Ensure that the gas flow from the base of the analyser is free of obstructions.
If a soot test is to be carried out, then the folowing is also needed:
G heated probe holder
G soot filters
G soot comparison scale
5.2.2 Switching on
Before use, the condition of the analyser should be checked:
G Check the filter element. Clean or replace as necessary.
G Check the state of charge of the battery if the analyser is to be operated from the internal
battery. This is carried out by switching on and reading the battery voltage or charge from
the initial screen, or from the screen MENU/OPTIONS/DEVICE INFO.
5.2.3 Switching off / Standby
Pressing the key [OFF] once will switch the analyser to the STANDBY mode.
In STANDBY mode the power consumption is drastically reduced. Amongst others the pump and the
backlight are switched off. Only the sensors remain supplied to be ready to operate immediately after the
instrument is switched on again.
The analyser does not switch to STANDBY mode if [OFF] is pressed in case:
G the key is being pressed during initial calibration. In that case the instrument notes the action,
but will switch to STANDBY only after the calibration is finished.
G the key is pressed while there is still a high gas concentration detected in the gas chamber. In
this case the instrument will automatically switch to FLOODING WITH AMBIENT AIR
mode and switch to STANDBY later on.
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 57 58

Comentários a estes Manuais

Sem comentários