Combustion Analyzers
ECA 450
• Industrial grade analyzer for both combustion efciency and emissions analysis
• Generates and prints combustion efciency and emissions reports
• Supports modular, eld-replaceable, sensors for O
2
, NO, NO
2
, SO
2
, CO and HC
• Expandable - add or change sensors as your requirements change
• Optional sensor upgrade kits available: CO (4,001
-
80,000 ppm) or HC (0
-
5%)
• Ideal for sampling and monitoring furnaces, boilers and other industrial
combustion equipment
• Comes standard in hard case, 12” sample probe assembly with
15' of hose and built-in printer; optional sample/condition probe.
The ECA 450, an industrial grade combustion efciency and environmental analyzer
compliant with EPA and state regulations, conducts accurate combustion and
emissions tests to ensure that industrial equipment is burning efciently and
environmental regulations are being met.
MEASUREMENT RANGE
Primary/Ambient Air Temperature –4° to 999° F (-20 to 537˚C)
Stack Temperature –4° to 2400° F (-20 to 1316˚C)
Draft / Differential -27.7 to +27.7 in. of H
2
0
Oxygen (O
2
) 0.0 to 20.9%
Carbon Monoxide (CO) (H
2
comp) 0 to 4,000 ppm
Carbon Monoxide (CO) (High Range)* 4,001 to 80,000 ppm
Nitric Oxide (NO)* 0 to 3,500 ppm
Nitrogen Dioxide (NO
2
)* 0 to 500 ppm
Sulfur Dioxide (SO
2
)* 0 to 4,000 ppm
Combustible Gases (HC)* 0 to 5.00% (application dependent)
SELECTABLE FUELS
Natural Gas, Propane, Coal, Wood, Kerosene, Oil #2, Oil #4, Oil #5,
Oil #6, Bagasse
CALCULATED RANGES RANGE
Combustion Efciency 0.1 to 100.0%
Excess Air 0 to 250%
Carbon Dioxide (dry basis) 0 to fuel dependent maximum
NO
x
(NO
x
= NO + NO
2
) 0 to 4,000 ppm
NO
x
referenced to % O
2
0 to 17,000 ppm
CO referenced to % O
2
0 to 99,999 ppm
NO referenced to % O
2
0 to 14,900 ppm
NO
2
referenced to % O
2
0 to 2,100 ppm
SO
2
referenced to % O
2
0 to 17,000 ppm
ORDERING INFORMATION
0024-7221 ECA 450 Base Unit (O
2
, CO, Ts, Ta, DP)
0024-8400 ECA 450 with NO / NO
2
sensors and compact sample
conditioner
0024-8401 ECA 450 with NO, NO
2
and SO
2
sensors and
compact sample conditioner
OPTIONAL ACCESSORIES
0024-3024 24” Probe Assembly
0024-3025 36” Probe Assembly
0024-7224 Compact Sample Conditioner/Probe
0024-3035 24” High Temperature Probe Assembly
0024-3036 36” High Temperature Probe Assembly
0024-3037 48” High Temperature Probe Assembly
0024-1124 20 Ft. Hose Extension with sample, draft and
thermocouple lines
0024-1172 Water Trap/Filter Assembly (for Probe Assemblies)
0007-1644 Replacement Filters for Water Trap (pkg of 3)
0007-1646 Replacement Filters for Compact Sample Conditioner/Probe
(pack of 5)
0007-1647 Replacement Filter for Peltier Cooler
0104-4027 Serial Cable DB 9M to DB 9F
0024-3150 High Temperature / High Dust Filter
0024-0980 Printer Paper (5 rolls)
OPTIONAL SENSOR UPGRADE KITS *
0024-3026 CO Sensor (4,001 to 80,000 ppm)
0024-3027 NO Sensor (0 to 3,500 ppm)
0024-3029 NO
2
Sensor (0 to 5,000 ppm)
0024-3030 SO
2
Sensor (0 to 4,000 ppm) - requires NO
2
Sensor to be
purchased
0024-3028 Combustible
Sensor (0 to 5%) - Oxygen dependent
OTHER SPECIFICATIONS
Power Universal AC adapter and an internal battery
pack. Adapter will accept input voltages
from 100 to 240V. Fully charged battery pack
provides a minimum of 8 hrs of operation
Size 13.5” H x 18.5” W x 9” D
(34.3 cm x 47 cm x 22.9 cm)
Weight 25 lbs (11.34 kg)
Memory Stores 1,900 test records
Display 160 x 160 pixels (2.5 in. x 2.5 in.) Liquid Crystal
Display
Warranty 1 year (does not include probe)
* Optional
*Factory installation required
Two pumps are included. The rst pump supplies gas sample to the
sensors. The second pump supplies fresh air to purge the low range CO
sensor when CO levels exceed 4000 ppm. Probe includes a standard
probe and hose assembly equipped with a water trap, particulate lter,
probe stop, 15 feet of hose and 12-inch probe tube.